Microscopy providers in Chelmsford, MA near me

Sem/edx services with MicroVision Laboratories, Inc. today? The client was able to obtain a comprehensive sampling of the state of the soldering process from the new manufacturer at a very reasonable cost. Rather than acquiring a mass of images, electrical test print outs, or low resolution optical pictures, the client received a comprehensive report detailing the relevant findings of the analysis on the boards from the new manufacturer. The solder joints in this study showed good bond integrity as well as excellent intermetallic layers. These findings allowed for the validation of the new manufacturer and their process which allowed for the clients device production to resume. The QC Engineers were very pleased with the customer service, analysis, pricing and quick turnaround time of this project.

Analysis and Results: The submitted bottle was examined for signs of interior distress, and the water from the bottle was removed and maintained. Some of the suspended particulate was filtered and examined non-destructively by light microscopy first, to characterize the material. A low magnification stereo microscope image of the filtered white particulate is shown in the image above. From this image, biological tissues were ruled out, and the material was observed to be crystalline. Polarized light microscopy (PLM) was used to analyze the sample next. From this examination, the material showed birefringence as shown in the PLM image on the right. The PLM Image Stereo Microscope image suspect material showed optical properties and morphology dissimilar to common carbonates and sulfates. It was determined to be a birefringent crystalline material, but it could not be identified using only PLM methods. Therefore, analysis using scanning electron microscopy with energy dispersive x-ray spectroscopy (SEM-EDS) would have to be performed to obtain further information about the suspect material.

Dust samples were analyzed using polarized light microscopy (PLM) to provide percentages of the particle types present in the samples. MVL was able to determine that there was significant loading of glass fibers in the dust samples with the likely source being contractor’s work in the attic which involved disturbing the fiberglass insulation. The image on the right shows a few distinct glass fibers with a binder material adhered to them, consistent with fiberglass insulation.

MicroVision Labs is owned and operated by a career microscopist, John Knowles, who understands the needs of our clients. Our emphasis on helping our clients solve problems, not just providing data, sets us apart from other labs. We have the technology and knowledge to find answers to your most difficult challenges, helping you succeed at every step. Can I come in to see my samples analyzed? Yes, our clients are always welcome to come in while their samples are being analyzed. For much of the work we do, it is mutually beneficial for our clients to be present to help direct their project since they can provide expertise about their samples. Some of the services we provide such as polished cross sections have time consuming steps making it impractical for a client to stay to watch everything. In those cases it is recommended that you come in initially to explain what you need done and come back at a later time to see the finished product. Discover extra details on Microvision labs website.

What is your standard turnaround time (TAT) and can it be expedited? Our standard TAT is 5 to 10 business days. We can provide faster TATs on request with the following surcharges: – Same day to 24 hour rush is 100% surcharge – 2 day rush is 75% surcharge – 3 day rush is 50% surcharge – 4 day rush is 25% surcharge Rush requests must have prior approval otherwise we cannot guarantee turnaround times.

Translucent or transparent coatings on metallic or semi-conductor substrates are very difficult to image due to their reflective nature. Nomarski/DIC imaging is an effective method for accentuating differences in thickness, density or the optical index in these cases. This analysis enhances and highlights subtle features with brilliant color gradients and captures them with a high resolution digital imaging system. Let us bring out your sample’s hidden features. Discover a few extra info at https://microvisionlabs.com/.